Stick a QR code on the alarm panel. Staff scan it, enter the venue PIN and tap OK: the weekly test is logged with their name, the time and the call point. Plus calm, practical help getting ready for Martyn's Law.
Weekly alarm testCP3 · Kitchen door · 09:02 · OK · Sam
Fire drill · booked 14:30
Fire drill14:30 · everyone out in 2m 41s
IllustrationNot to scale
01Two jobs, one log book
Fire safety records all year. Martyn's Law when it lands.
Fire safetyAll year · duty to maintain
The records a fire officer usually asks to see, kept as you go.
In England and Wales, the Regulatory Reform (Fire Safety) Order 2005 says the responsible person must keep fire safety measures maintained - and records are how you show it. Scotland and Northern Ireland have their own fire safety laws with similar duties. Muster turns the paper log behind the bar into a 20-second tap.
Weekly alarm tests with automatic call-point rotation
Monthly emergency lighting and extinguisher checks
Contractor visits and certificates, drills and staff training
Faults tracked from report to fix
Martyn's LawExpected spring 2027
Know your tier. Write your procedures. Brief your team.
The Terrorism (Protection of Premises) Act 2025 applies to premises where 200 or more people may be present at once. Muster helps you get ready without the jargon - or the scare stories.
Free tier checker with a plain-English result
Guided builder for your public protection procedures
Staff briefing sheet with one-click sign-off
A checklist of what the SIA will ask when you notify
02Tap to log
Twenty seconds at the panel.
No app, no logins, no lost pen. The sticker knows which check it is, the phone remembers who you are, and Muster has already picked the call point.
Step 1
Walk to the panel
The sticker lives on the fire alarm panel, where the weekly test happens.
Step 2
Scan the QR
Any phone camera. Enter the four-digit venue PIN once - the phone remembers it - and pick your name.
Step 3
Name logged
Test the call point Muster suggests, then tap OK or report a fault. Your name, the time and the call point go in the log book.
Try it on your phone. Scan the code, or open the demo. The PIN is 1234 - nothing is saved.
Test this call pointCP3Kitchen door · next in rotation
Sounded OK
Report a fault
Logged
Weekly alarm test CP3 · 09:02 · OK · Sam
Next week: CP4 · Function room
03The check schedule, built for you
What gets checked, and how often.
Tell Muster what's in your building (call points, emergency lighting, extinguishers) and it builds your schedule, works out what's due, and reminds you before anything slips.
Weekly
Weekly fire alarm test
Set off the alarm from a different call point each week (use the test key), check it sounds everywhere in the building and resets properly. Tell everyone first so nobody evacuates.
Staff · QR tap
Weekly
Escape routes & fire doors
A weekly walk-round of every escape route: nothing blocking corridors or exits, final exits open easily without a key, fire doors close fully on their own, exit signs are lit and in place. GOV.UK also suggests checking exits are unlocked and routes are clear every day, as part of opening up.
Staff · QR tap
Monthly
Monthly emergency lighting test
Use the test key (or flick switch) to cut the mains supply and check every emergency light comes on. Keep it brief, then restore the supply so the batteries recharge.
Staff · QR tap
Monthly
Monthly extinguisher check
Check each extinguisher is in its place, unobstructed, the pin and tamper seal are intact, any pressure gauge reads in the green, and there's no visible damage.
Staff · QR tap
6-monthly
Fire alarm service
Inspection and testing of the whole fire alarm system by a competent contractor, at least every six months.
Contractor
Yearly
Emergency lighting annual test
Full-duration test and inspection of the emergency lighting by a competent person, once a year.
Contractor
Yearly
Extinguisher service
Every extinguisher inspected and tested by a competent contractor, once a year.
Contractor
Every 6 months (default)
Fire drill
Run a fire drill: sound the alarm, time how long it takes to get everyone out to the assembly point, and note anything that slowed people down. GOV.UK suggests periodic drills (for example once a year); your fire risk assessment, licence or insurer may set how often. Muster's default is every six months.
You
Yearly (default)
Fire risk assessment review
Keep your written fire risk assessment under regular review (Muster reminds you yearly, a common good-practice default), and review it straight away after any significant change (layout, use, occupancy, a fire or near miss).
Responsible person
Test and servicing intervals follow GOV.UK's Making your small non-domestic premises safe from fire (updated January 2025), a guide for England; Wales, Scotland and Northern Ireland have their own guidance with similar intervals. That guide also asks for a daily check that exits are unlocked and escape routes are clear, as part of opening up: Muster's weekly sticker records a fuller walk-round. GOV.UK doesn't fix how often to run drills (it suggests periodic drills, for example once a year) or review your fire risk assessment (regularly), so those two are Muster's defaults. Your fire risk assessment, licence, insurer or contractor may set different intervals - you can adjust drills, and every date is editable.
04Martyn's Law
Ready in an afternoon. Not a panic in spring.
The main duties of the Terrorism (Protection of Premises) Act 2025 are expected to come into force in spring 2027. For most venues in scope, they're sensible and achievable: tell the regulator, and have clear procedures that your team knows.
3 April 2025
The Terrorism (Protection of Premises) Act 2025 receives Royal Assent.
April to October 2026
The statutory guidance (April) and the SIA's guidance powers (June) come into force, and regulations set the notification rules (July) and how to decide a building's principal use (October).
Autumn 2026
The SIA publishes its final guidance and consultation report.
Early 2027 (planned)
The SIA invites volunteers to test its notification portal before launch.
Spring 2027 (expected)
The main duties are expected to come into force, after an implementation period of at least 24 months.
Within 3 months of commencement
Existing qualifying premises must notify the SIA (set by the Notification Requirements Regulations 2026).
Under 200 people
Not in scope
No Martyn's Law duties - though simple emergency procedures are still good practice.
200–799 people
Standard tier
Notify the SIA and have public protection procedures that your staff know. Penalties up to £10,000, plus up to £500 a day.
800+ people
Enhanced tier
Everything in standard, plus protective measures and a documented plan. Places of worship, schools, further education and childcare stay standard tier.
Numbers include staff: the most people reasonably expected at the same time. Source: GOV.UK - Understanding Martyn's Law, the statutory guidance and the Home Office factsheets. We watch the official guidance and email Muster customers when it changes.
Four procedures Muster helps you write
E
Evacuation
Getting people out and away from danger - which exits, who sweeps which rooms, where you gather.
I
Invacuation
Moving people to a safer place inside when the danger is outside - away from glass, into the right rooms.
L
Lockdown
Securing the building so nobody can get in or out - which doors, how they lock, who does it.
C
Communication
How staff alert each other, how you tell the public, and who calls 999 with what information.
The Act is known as Martyn's Law in memory of Martyn Hett, who was killed in the Manchester Arena attack in 2017. His mother, Figen Murray, campaigned for years for venues to be better prepared. We try to write about it with the care that deserves.
05Inspection-ready
When the fire officer calls, it's one click.
The inspection pack bundles your fire safety records into a single printable document - or a PDF to email to your insurer or licensing officer. Keep your fire risk assessment alongside it.
Venue summary and equipment
The last 12 months of checks, by date
Faults and the actions that closed them
Contractor visits, drills and training records
Your Martyn's Law procedures and staff sign-offs
Example venue · dashboard
94%On time last 90 days
Example figures, for illustration
Weekly fire alarm testUp to date
Emergency lighting testDue in 3 days
Fire alarm serviceUp to date
Fire drillOverdue by 4 days
Fire safety refresher · 2 staffDue this month
09:02 · CP3 · OK · Samvia QR
06Pricing
14 days free. Then £12 a month.
Every plan starts with a 14-day free trial. Add your card at checkout and nothing is taken for 14 days; cancel before then and you pay nothing. Sign up, set up your venue and print your stickers first, then choose.
Recommended
Venue
The complete log book and Martyn's Law toolkit for one venue.
No. Your fire risk assessment is a written assessment of your premises by you or a competent assessor. Muster keeps the records that show you're maintaining the fire safety measures it relies on (tests, servicing, drills, training and faults) and reminds you when the assessment is due for review.
Do staff need an account or an app?
No. Staff scan the QR sticker with their phone camera, enter your four-digit venue PIN once, pick their name and tap the result. Nothing to install, no passwords to forget.
What happens if someone enters the wrong PIN?
After five wrong attempts from the same phone, the logging page locks for 15 minutes. You can change the PIN at any time, which also signs out every phone that used the old one.
Why does it suggest a different call point each week?
GOV.UK's fire safety guide for small premises in England says to test the fire alarm using a different manual call point each week (Wales, Scotland and Northern Ireland have their own guidance with similar intervals). Muster suggests the call point that was tested longest ago, so every one gets tested in rotation.
Will Muster make us compliant with Martyn's Law?
Muster helps you prepare: it works out your likely tier, guides you through writing public protection procedures, records staff briefings and lists what you'll need to notify the SIA. Whether your arrangements are appropriate is for you (and ultimately the regulator) to judge - Muster is guidance and record-keeping, not legal advice.
When does Martyn's Law come into force?
The Terrorism (Protection of Premises) Act 2025 received Royal Assent on 3 April 2025. The government expects its main duties to come into force in spring 2027, after an implementation period of at least 24 months. The Notification Requirements Regulations 2026 then give existing premises in scope three months to notify the SIA. We watch the official guidance and email Muster customers when it changes.
Can I print our records for the fire officer?
Yes. The inspection pack bundles your venue details, the last 12 months of checks, faults and actions, contractor visits, drills, training records and your procedures into one printable document - save it as a PDF in one click. It holds the records a fire officer usually asks to see; keep your fire risk assessment alongside it.
How does the free trial work?
Every plan starts with a 14-day free trial. You add a card at Stripe's secure checkout, nothing is taken for 14 days, and if you cancel before then you pay nothing. The trial is once per account. You can sign up, set up your first venue and print your QR stickers before you choose a plan; staff can log checks once your plan or trial is on.
We have more than five venues. What does that cost?
Multi-site covers up to five venues. Each venue over five is £5 a month (or £50 a year on annual billing), and you add them yourself on the billing page, as many as you need.
Can I cancel, and can I get a refund?
Cancel any time from the billing portal in a couple of clicks: your plan runs to the end of the period you've paid for and you won't be charged again. Payments aren't refundable. Nothing is deleted when a plan ends: every record stays there to view and export (log book spreadsheet and inspection pack), but staff can't log new checks and reminders stop until you choose a plan again.